87
CTC EcoZenith i360
12.10.2 Settings Heat pump
Compressor
Blocked (Permitted/Blocked)
The heat pump is supplied with a blocked compressor.
"Permitted" means that the compressor can start.
Brine pump
Auto (Auto/10 days/On)
After installation is complete, you can choose to run the
brine pump constantly for 10 days to remove air from
the system. The brine pump then enters "Auto" mode.
"On" means the brine pump runs constantly.
Only applies to liquid-to-water heat pumps.
Stop at outdoor temp °C
-22 (-22...10)
This menu relates to settings for the outdoor
temperature at which the compressor is no longer
permitted to operate. The heat pump starts 2°C above
the set value.
Only applies to air-to-water heat pumps.
Compressor stop at brine °C
-5 (-7...10)
This menu defines the brine temperature at which the
compressor will be stopped.
Only applies to liquid-to-water heat pumps.
Tariff HP
No (No/Yes)
"Yes" means the function can be activated via remote
control.
Read more in the "Def. Remote Control" section of the
"Installer / Define" chapter.
Tariff HP schedule
This menu bar is displayed if a weekly program has
been defined for the "HP Tariff" function.
For more information, refer to:
• chapter "Weekly Program" for schedule setting.
• section "Def. Remote Control" of the
"Installer / Define" chapter for defining the remote
control function.
SmartGrid block HP
No (No/Yes)
Read more in the "Remote Control /SmartGrid" section
of the "Installer/Define" chapter.
Start at degree minute
-60 (-900...-30
This states the degree minute at which the heat pump
will start.
HS<->DHW time (sec)
120 (30...240)
Time in seconds for which the compressor maintains a
constant speed while switching between heating and
hot water.
Menu: "Installer/Settings/Set". Heat pump.
Содержание EcoZenith i350 L 1x230V
Страница 3: ...162 505 77 1 2020 09 15 Installation and Maintenance Manual CTC EcoZenith i360 ...
Страница 127: ...127 CTC EcoZenith i360 ...
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 77 1 2020 09 15 ...