9. Operation and Maintenance
Automatic bleeder
Safety valve
Manometer
Automatic bleeder
Serial number for registration
and fault reporting behind
magnetic strip.
Solenoid fi lter ball valve
Dirt fi lter for
tap water
Filling valve
Touchscreen
Serial number
Drainage valve
The installation engineer together with the property owner must check that the
system is in perfect operating condition. The installation engineer must show the
switches, controls and fuses to the property owner so that the owner knows how
the system works and how to service it. Bleed the radiators after approximately
three days of operation. Fill with water as needed via the filling valve if the
manometer shows that the system pressure is too low.
Operation stop
The product is turned off using the omnipolar switch. If there is a risk of the water
freezing, all the water should be drained from the heat pump and the heating
circuit.
Draining the tank
The product should be disconnected from the power source while it is being
drained. The draining valve for the low model is situated in the bottom right as
viewed from the front, behind the product’s front panel. For the high model, the
drainage valve is included in the additional pack and the pipe installation engineer
chooses where to connect the valve. Air must be supplied to the closed system.
Boiler and heating circuit bleeding/safety valve
Check around four times a year that the valve is working correctly by manually
turning the control. Check that there is water and not air coming out of the waste
pipe; if air is coming out then the tank will need to be bled. Open the screw on the
automatic bleeder for the first few months; the screw should then be closed to
avoid damaging the bleed valve.
Cleaning the dirt fi lter and solenoid fi lter ball valve
Regularly clean the dirt filter (close off incoming tap water, remove and clean the
filter) and solenoid filter ball valve (close off the flow to the heat pump, remove and
clean the filter).
Содержание EcoZenith i350 L 1x230V
Страница 3: ...162 505 77 1 2020 09 15 Installation and Maintenance Manual CTC EcoZenith i360 ...
Страница 127: ...127 CTC EcoZenith i360 ...
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 77 1 2020 09 15 ...