13.4
Alarm messages
If a fault occurs with e.g. a sensor, an alarm is triggered. A message appears on the
display with information about the fault.
You reset the alarm by pressing the Reset Alarm button on the display. If several alarms
are triggered, they are displayed one after the other. A persisting fault must first be
rectified before it can be reset. Some alarms are reset automatically if the fault ceases.
Alarm messages
Description
[E010] Compressor type ?
This message appears if no information about the compressor type is available.
[E013] EVO off
This message appears when there is a fault with the expansion valve control.
[E024] Fuse blown
This message appears when the fuse (F1, F2) has been triggered.
[E026] Heat pump
This message appears if the heat pump is in alarm mode.
[E027] Communication error
HP
[E063] Comm. err. relay board
[E056] Comm. err. motor
protection
[E086] Comm. err. expansion
card
This message is displayed when the display card (A1) cannot communicate with the
HP control card (A5).
This message is displayed when the display card (A1) cannot communicate with the
relay card (A2).
This message is displayed when the HP control card (A5) cannot communicate with
the motor protection (A4).
This message is displayed when the display card (A1) cannot communicate with
CTC Solar control/Expansion card (A3).
[E035] High pressure switch
The refrigerant’s high pressure switch has been triggered. Press reset and check
whether the alarm recurs. If the fault recurs, contact your installer.
[E040] Low brine flow
Low brine flow is often caused by air in the collector system, especially immediately
following installation. Collectors which are too long can also be a cause. Press
reset and check whether the alarm recurs. Also check the brine filter that has been
installed.
If the fault recurs, contact your installer.
[E041] Low brine temp
Incoming brine temperatures from bore hole/ground loop are too low. Press reset
and check whether the alarm recurs. If the fault recurs, contact your installer to
check the dimensions of the cold side.
[E044] Stop, high compr temp
This message appears when the compressor temperature is high.
Press reset and check whether the alarm recurs. If the fault recurs, contact your
installer.
[E045] Stop, low evaporation
This message appears when the evaporation temperature is low.
Press reset and check whether the alarm recurs. If the fault recurs, contact your
installer.
[E046] Stop, high evaporation
This message appears when the evaporation temperature is high.
Press reset and check whether the alarm recurs. If the fault recurs, contact your
installer.
[E047] Stop, low suct. gas exp.
valve
This message appears when the suction gas temperature is low.
Press reset and check whether the alarm recurs. If the fault recurs, contact your
installer.
[E048] Stop, low evap. exp.
valve
This message appears when the expansion valve’s evaporation temperature is low.
Press reset and check whether the alarm recurs. If the fault recurs, contact your
installer.
Содержание EcoZenith i350 L 1x230V
Страница 3: ...162 505 77 1 2020 09 15 Installation and Maintenance Manual CTC EcoZenith i360 ...
Страница 127: ...127 CTC EcoZenith i360 ...
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 77 1 2020 09 15 ...