104
CTC EcoZenith i360
12.11.1.2 Remote control functions
The "Installer/Define/Remote Control" menu defines
Inputs for current remote control functions:
• Inputs K22, K23, K24, K25.
• wireless accessories in the SmartControl series
(Channel 1A, 1B, 2A, 2B, 3A, 3B and so on up to
7B).
• BMS digital input 0-7. Specify a value 0-255. The
value must be set again within half an hour for the
setting to persist.
Ethernet
(Modbus TCP/Off)
For information about Modbus TCP Port settings,
refer to the "Communication" section in the "Installer/
Settings" chapter.
Night reduction (HC1-HC2)
(Off/ K22-K25 /Channel 1A-7B / BMS DI0-7)
The "Night Reduction" function can be used to, for
example, lower the indoor temperature during the night
or during working hours.
In the "Installer / Define/Remote Control" menu:
• specify an "Input" for the remote control function.
In the "Installer / Define/Heating Circuit" menu:
• configure the normal mode for the external control
signal (Normally Open (NO)/Normally Closed (NC)).
The weekly program can be set in the "Heating/Cooling"
menu.
For more information, refer to the "Night Reduction
Temperature" section in the "Heating/Cooling" chapter.
Heating mode, ext (HC1-HC2).
(Off/ K22-K25 /Channel 1A-7B / BMS DI0-7)
Switching between heating season and summer season
can take place at a specific outdoor temperature (Auto)
or heating can be either always "On" or "Off".
In the "Installer / Define/Remote Control" menu:
• specify an "Input" for the remote control function.
In the "Installer / Define/Heating Circuit" menu:
• configure the normal mode for the external control
signal (Normally Open (NO)/Normally Closed (NC)).
In the "Installer /Settings/Heating Circuit" menu:
• set "Remote Control Mode" ("On", "Off" or "Auto")
in the "Heating mode, ext." row.
Access function scheduling from the "Heat mode,
schedule" row.
For more information, refer to the "Heating Circuit"
section in the "Installer/Settings" chapter.
Also refer to the "Your home’s heating settings" chapter.
Part of the "Installer / Define/Remote Control" menu.
"Input" and "Weekly Program" are defined here.
Menu: "Installer/Settings/Heating Circuit". The remote control
mode for the heating circuit is set on menu bar "Heating mode,
ext". Access the weekly program from the menu bar "Heating
mode, schedule".
Содержание EcoZenith i350 L 1x230V
Страница 3: ...162 505 77 1 2020 09 15 Installation and Maintenance Manual CTC EcoZenith i360 ...
Страница 127: ...127 CTC EcoZenith i360 ...
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 77 1 2020 09 15 ...