108
CTC EcoZenith i360
SmartGrid functions are enabled by activating the
SmartGrid inputs in different ways according to the table
on the right.
To enable the SmartGrid function "SG Low Price"
as shown in the example, terminal block K23 must
have power while terminal block K22 should remain
unchanged.
The pool temperature increase that will apply when
"SG Low Price" is activated is set in the "Pool Settings"
menu, as shown in the example.
Alternatively, a weekly program can be set up for
periodic SmartGrid activation. For more information
on setting schedules, refer to the "Weekly Program"
section.
Tariff HP
(Off/ K22-K25 /Channel 1A-7B / BMS DI0-7)
This function is used to block the heat pump during
periods when the electricity rate is higher.
In the "Installer / Define/Remote Control" menu:
• specify an "Input" for the remote control function.
In the "Installer / Define/Heat Pump" menu:
• configure the normal mode for the external control
signal (Normally Open (NO)/Normally Closed (NC))
in the "Tariff HP ext. config." row.
In the "Installer/Settings/Heat Pump" menu:
• set "Tariff HP" ("On").
For more information, refer to the "Heating Pump"
section in the "Installer/Settings" chapter.
The schedule is set to start at 22:30, weekdays.
K22 (SG A)
K23 (SG B)
Function
Open
Open
Normal
Open
Closed
Low price
Closed
Closed
Overcapacity
Closed
Open
Blocking
Menu: "Installer/Define/Heat Pump".
A mode for the external control signal ("Normally Open (NO)"
or "Normally Closed (NC)") is defined for "Tariff HP ext. config.",
"Noise reduction ext. config." and "Silent mode ext. config.".
Содержание EcoZenith i350 L 1x230V
Страница 3: ...162 505 77 1 2020 09 15 Installation and Maintenance Manual CTC EcoZenith i360 ...
Страница 127: ...127 CTC EcoZenith i360 ...
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 77 1 2020 09 15 ...