115
CTC EcoZenith i360
12.12 Service
12.12.1
Function test
From this menu, the installer can test the connection
and function of separate components of the heating
circuit. When this menu is activated, all control functions
are stopped. The only protection against incorrect
operation is the pressure sensors and the electric
heater’s overheating protection device. The heat pump
returns to normal operation after 10 minutes of inactivity
or when exiting the "Function Test" menu. When the
menu is opened, all automatic functions are stopped
and testing can be performed.
i
When you exit the menu, the heat
pump returns to normal operation.
!
NB: This menu is intended for the
installer only.
12.12.1.1 Test Heating circuit
If several heating circuits have been installed, they will all
be displayed here.
Rad. pump (1-)
Off (On/Off)
Starts and stops the respective radiator pump.
Mixing valve (1-)
Close (Close/Open)
Opens and closes the respective mixing valve.
LED room sensor
Off (On/Off)
The room sensor alarm functions can be controlled from
here. When activated, the respective room sensor’s red
LED comes on steady.
Menu: "Installer/Service".
Menu: "Installer/Service/ Function Test".
Menu: "Installer/Service/ Function Test/Heating Circuit".
Содержание EcoZenith i350 L 1x230V
Страница 3: ...162 505 77 1 2020 09 15 Installation and Maintenance Manual CTC EcoZenith i360 ...
Страница 127: ...127 CTC EcoZenith i360 ...
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 77 1 2020 09 15 ...