116
CTC EcoZenith i360
Menu: "Installer/Service/ Function Test/Heat Pump".
Menu: "Installer/Service/ Function Test/Valves".
12.12.1.2 Test Heat pump
HP Compressor
Off (On/Off)
When the compressor is being function tested, the
brine and charge pump are also operating so that the
compressor does not trigger its pressure switches.
HP Brine Pump/Fan
Off (Off/On)
Function test brine pump or fan (air-to-water heat
pump).
HP Charge Pump
Off (Off/On/ 0...100%)
Function test charge pump 0–100%.
Defrost Manually
Off (Off/On)
When the "Manual defrosting" function is tested, a
defrosting cycle will be performed in the air-to-water
heat pump. Defrosting cannot be stopped once it has
been started and the defrosting programme will be
completed.
Compressor heat
Off (Off/On)
Function test compressor heater.
Drip tray heater
Off (Off/On)
Function test of the condenser tray heater.
Heating Cable
Off (Off/On)
Function test heating cable.
4-way valve (Y11)
Off (Off/On)
Function test 4-way valve (Y11). Fitted to air-to-water
heat pump.
12.12.1.3 Test Valves
The following valves are function tested from this menu:
3-way valve
HS/DHW
12.12.1.4 Test Electric heaters
Tests the electric heaters per phase and step (On/Off).
Electric heater L1A
Off (Off/On)
Electric heater L1B
Off (Off/On)
Electric heater L2A
Off (Off/On)
Electric heater L2B
Off (Off/On)
Electric heater L3A
Off (Off/On)
Electric heater L3B
Off (Off/On)
Electric heater A13
Off (Off/On)
Menu: "Installer/Service/ Function Test/Electric Heaters".
Содержание EcoZenith i350 L 1x230V
Страница 3: ...162 505 77 1 2020 09 15 Installation and Maintenance Manual CTC EcoZenith i360 ...
Страница 127: ...127 CTC EcoZenith i360 ...
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 77 1 2020 09 15 ...