CTC EcoZenith i360
System 2
System 2 is a system structure with solar heat connected to an external heat
source tank (EHS tank) and an extra buffer tank (CTC VT 80 for example).
The system allows for a larger solar collector surface since it carries a greater
volume of water.
Charging conditions
• Charging starts when B31 is 7°C warmer than B42.
• Buffer tank
without
coil:
• Charging stops when there is a difference of 3°C between B31/B30 or
when the charge temperature is reached.
• Buffer tank
with
coil:
• For a tank with a solar coil, the charging stops instead when B31 is
3°C warmer than B42.
• Charging of the EHS tank compares sensor B41 to sensor B47.
The buffer tank (02) may also have a solar coil; this means that the heat
exchanger (F2), pump (G32) or non-return valve (Y11) is not required.
System 3
System 3 is a system structure with an extra volume called 03; this can be a
large extra tank or a pool. The greater the water volume, the larger the solar
collector surface required.
System 3 is solar heat connected to an external heat source tank (EHS-
tank) and an extra buffer tank. The system allows for a larger solar collector
surface since it carries a greater volume of water.
Charging conditions
• Charging starts when B31 is 7°C warmer than B42 or B47.
• Charging stops when there is a difference of 3°C between B31/B30 or
when the charge temperature is reached.
11.5.9
CTC EcoVent (accessory)
To connect the CTC EcoVent ventilation product, please refer to the CTC
EcoVent manual.
11.5.10
CTC SmartControl (accessory)
To connect CTC SmartControl, please refer to the CTC SmartControl
manual.
Содержание EcoZenith i350 L 1x230V
Страница 3: ...162 505 77 1 2020 09 15 Installation and Maintenance Manual CTC EcoZenith i360 ...
Страница 127: ...127 CTC EcoZenith i360 ...
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 77 1 2020 09 15 ...