AC Repair and Adjustment Procedures
FRP 14: Module-to-WACS Cable Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
99
FRP 14: Module-to-WACS Cable Replacement
The easiest way to remove a PEM-to-WACS or clock-to-WACS cable assembly
is to drop the associated rail connector (where the wires from the cable assembly
connect) into the card cage. This provides improved access (through the card
cage) to the 2-pin connectors on the wires.
Wiring procedures are more efficient when two people work together. The
individuals can share tasks and check one another’s work.
Part Number
•
One of the following cable assemblies:
•
15214200 (cable assembly, PEM to WACS)
•
57263800 (cable assembly, clock to WACS)
•
01775900 (pin connector lock)
Tools Required
•
2-mm, 4-mm, and 5-mm hex (allen) wrenches with hex driver
•
#1 and #2 Phillips screwdrivers
•
Camming tool
•
Small and medium flatblade screwdrivers
•
0.05-in. hex (allen) wrench with torque driver
•
0.3-mm mechanical pencil, with no lead (or a wire removal tool)
•
Flashlight
•
Dental pick
•
Tweezers (optional)
•
Hemostats (forceps) or another wire insertion tool (all optional)
•
Cutters/snips