FRP 21: Clock Switch Board Replacement
AC Repair and Adjustment Procedures
126
Cray Research/Silicon Graphics Proprietary
HMM-168-A
FRP 21: Clock Switch Board Replacement
If a Clock Select switch or the Boundary Scan Enable switch fails, you must
replace the entire clock switch board.
Part Number
•
57253600 (PC board assembly, T3E switch -- clock switch board)
Tools Required
•
Small flatblade screwdriver
•
#1 Phillips screwdriver
•
7-mm wrench
Switch Removal
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet. Place a lockout device over the cabinet’s plug and lock/tag it.
CAUTION
Observe all ESD precautions. Failure to
do so could result in damage to the
equipment.
WARNING
Ensure that the electrical plug for the
equipment that you service is
unplugged, locked, and tagged. Failure
to do so could result in severe shock
and burns.