AC Repair and Adjustment Procedures
FRP 31: Power Supply Circuit Breaker (CB2 through CB7)
HMM-168-A
Cray Research/Silicon Graphics Proprietary
163
4.
Insert the input wires into the bottom of the circuit breaker. Hold the
breaker firmly and tighten the screw clamps securely.
5.
Ensure that all screw clamps on the circuit breaker are tight.
6.
Position the circuit breaker appropriately, then replace the breaker box
cover and secure it with screws and washers.
7.
Replace the air filter.
8.
Return the system to operation and close the front cabinet door.