FRP 3: Power Supply Replacement
AC Repair and Adjustment Procedures
28
Cray Research/Silicon Graphics Proprietary
HMM-168-A
b. Insert the male power-cord connector in the exposed receptacle, then
release the mechanical interlock.
c. Insert the other power-cord connector in the receptacle on the power
supply.
5.
Close the power supply circuit breaker.
6.
When you are ready to apply power to this module slot, take all necessary
steps to restore the associated module to a functional state.
For example, reconfigure the torus configuration and press the Restart
button (switch) on the WACS panel. When you press the Restart button,
the WACS sends enable signals to all power supplies with functional
modules. This does not adversely affect power supplies that are already
powered up.
7.
Close the front door of the cabinet.