AC Repair and Adjustment Procedures
FRP 23: Inlet Air Thermistor Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
135
6.
Power on the cabinet and test the thermistor as follows:
With the WACS on and the blower and power supplies off, check the
temperatures on the WACS display. Then apply heat to the new thermistor
(for example, apply body heat with your hand) and check the temperature
change on the WACS display.
7.
Replace the panel, return the cabinet to operation, and close the door.