AC Repair and Adjustment Procedures
FRP 26: WACS Scanner Fuse Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
145
FRP 26: WACS Scanner Fuse Replacement
Part Number
•
01134006 (fuse, 250V 1/2 amp)
Tools Required
•
Small flatblade screwdriver
Fuse Replacement
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet. Place a lockout device over the cabinet’s plug and lock/tag it.
You may also open, lock, and tag the customer’s wall breaker(s).
3.
Open the WACS circuit breaker (CB9).
4.
Open the WACS panel and locate the defective scanner fuse.
WARNING
Ensure that the electrical plug for the
equipment that you service is
unplugged, locked, and tagged. Failure
to do so could result in severe shock
and burns.