FRP 30: WACS Panel Circuit Breaker (CB8, CB9, or CB10) Replacement
AC Repair and Adjustment
Procedures
156
Cray Research/Silicon Graphics Proprietary
HMM-168-A
FRP 30: WACS Panel Circuit Breaker (CB8, CB9, or CB10)
Replacement
Part Number
One of the following parts:
•
57176102 (circuit breaker, 3A -- WACS or auxiliary)
•
57176101 (circuit breaker, 10A -- blower)
Tools Required
•
#1 Phillips screwdriver
•
#2 Phillips screwdriver
•
Small flatblade screwdriver
Circuit Breaker Removal
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet. Place a lockout device over the cabinet’s plug and lock/tag it.
You may also open, lock, and tag the customer’s wall breaker(s).
3.
Open the WACS panel.
4.
Note the positions of the wires that connect to the defective circuit
breaker.
WARNING
Ensure that the electrical plug for the
equipment that you service is
unplugged, locked, and tagged. Failure
to do so could result in severe shock
and burns.