AC Repair and Adjustment Procedures
FRP 33: Time-delay Relay Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
169
b. Pull the cover straight up, then remove it from the cabinet. Be careful
not to damage the inlet air thermistors or the EMI gasket on the bottom
of the cover.
5.
Record the locations of the wires that connect to the relay, and remove the
wires with a medium flatblade screwdriver.
6.
Use a #1 Phillips screwdriver (some cabinets may require a 2.5-mm hex
driver) to remove the screws that hold the relay to the bottom of the power
box, then remove the relay.
Figure 76. Time-delay Relay Location
Installation
1.
Set the replacement relay to match the settings on the defective relay.
2.
Secure the replacement relay in the power box with the Phillips (or hex)
screws.
3.
Connect the wires to the relay. Refer to your notes for the correct
locations.
4.
Replace the power box cover and the air filter.
5.
Restore the cabinet to operation and close the front cabinet door.
Cabinet Front
(power supply insertion side)
Time-delay
Relay
Cabinet Rear
(module insertion side)