AC Repair and Adjustment Procedures
FRP 36: Resistor (R1) Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
177
You may also open, lock, and tag the customer’s wall breaker(s).
3.
Remove the air filter to provide greater access to the power box. Refer to
for removal instructions.
4.
Remove the cover from the power box:
a. Use a #2 Phillips screwdriver to remove the screws that hold the cover
in place.
b. Pull the cover straight up, then remove it from the cabinet. Be careful
not to damage the inlet air thermistors or the EMI gasket on the bottom
of the cover.
5.
Use wire cutters to cut the 2 wires that connect to R1. Cut the wires as
close as possible to R1.
6.
Use a #1 Phillips screwdriver to remove the 2 screws that secure R1 to the
side of the power box.
Figure 79. Resistor Location
Cabinet Front
(power supply insertion side)
Cabinet Rear
(module insertion side)
Resistor