AC Repair and Adjustment Procedures
FRP 25: Thermostat Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
141
FRP 25: Thermostat Replacement
Two people are required if you plan to test the new thermostat with a heat gun.
The thermostats receive line voltage. Ensure that the main disconnect circuit
breaker (CB1) is open before you perform this procedure.
Part Number
•
57199700 (thermostat, 65 degree C)
Tools Required
•
#1 and #2 Phillips screwdrivers
•
Multimeter (ohmmeter)
•
Heat gun (optional)
Thermostat Removal
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet. Place a lockout device over the cabinet’s plug and lock/tag it.
WARNING
Open the cabinet’s main disconnect
circuit breaker (CB1) before you
perform this procedure. Failure to do
so could result in severe shock and
burns.