FRP 14: Module-to-WACS Cable Replacement
AC Repair and Adjustment Procedures
100
Cray Research/Silicon Graphics Proprietary
HMM-168-A
Wire Removal
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet. Place a lockout device over the cabinet’s plug and lock/tag it.
You may also open, lock, and tag the customer’s wall breaker(s).
3.
Open the rear cabinet door.
4.
Loosen the eight 1/4-turn captive screws that secure the module panel,
then pull the module panel out of the cabinet at an angle.
5.
Remove panels to provide access to the wire:
If you are replacing a PEM-to-WACS cable:
Disconnect the cable from the clock switch board, remove the blower
exhaust shield, and remove the upper plenum panel. (Six #2 Phillips
screws hold the blower exhaust shield in place. Six #1 Phillips screws
hold the upper plenum panel in place.)
If you are replacing a clock-to-WACS cable:
Remove the I/O panel, loosen the I/O bulkhead, and remove the lower
plenum panel. (Eight 1/4-turn captive screws secure the I/O panel to the
cabinet. Six #1 Phillips screws hold the I/O bulkhead in place. Twelve #1
CAUTION
Observe all ESD precautions. Failure to
do so could result in damage to the
equipment.
WARNING
Ensure that the electrical plug for the
equipment that you service is
unplugged, locked, and tagged. Failure
to do so could result in severe shock
and burns.