AC Repair and Adjustment Procedures
FRP 10: Logic Cable Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
65
FRP 10: Logic Cable Replacement
To remove a logic cable, you must first remove the plastic slot guide from the
rail. The slot guide is secured by 7 nylon screws. You will remove the cable
while the rail remains mounted in the chassis.
Part Number
•
15112904 (X-dimension ribbon cable assembly)
•
15112905 (Y-dimension ribbon cable assembly)
•
15112906 (Z-dimension ribbon cable assembly)
Tools Required
•
2-mm, 4-mm, and 0.05-in. hex (allen) wrenches with torque driver
•
#1 and #2 Phillips screwdrivers
•
Medium flatblade screwdriver
•
Tweezers (optional)
Cable Removal
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet. Place a lockout device over the cabinet’s plug and lock/tag it.
CAUTION
Observe all ESD precautions. Failure to
do so could result in damage to the
equipment.