AC Repair and Adjustment Procedures
FRP 18: WACS Panel Switch (SW6, SW7, SW8) Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
121
5.
Mark the switch to identify it as defective.
6.
Squeeze the flanges on the left side of the switch body together as you
push the left side of the switch through the cutout (switch hole) in the
WACS panel. Refer to
Figure 58. Switch Removal
7.
Squeeze the flanges on the right side of the switch body together as you
push the right side of the switch through the cutout in the WACS panel;
then carefully remove the switch from the cutout in the WACS panel.
Switch Installation
1.
Carefully move the wires from the defective switch to the replacement
switch, one wire at a time. Then set the defective switch aside. (You may
want to use a pair of needlenose pliers to assist you in removing the wires
from the defective switch.)
2.
After you install the wires on the replacement switch, push the switch
through the cutout in the WACS panel. The flanges on the switch will lock
the switch in place.
3.
Close the WACS panel.
4.
Return the cabinet to operation and check the switch function.
5.
Close the front cabinet door.
CAUTION
The wires and connectors damage easily. Be careful not
to kink or break the wires or to damage the connectors.
WACS
Panel
Switch
NOTE: View is from Cabinet Top
Step 6
Step 7