AC Repair and Adjustment Procedures
FRP 21: Clock Switch Board Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
127
You may also open, lock, and tag the customer’s wall breaker(s).
3.
Open the rear cabinet door.
4.
Use a small flatblade screwdriver to disconnect the cable from the clock
switch board. Two screws secure the cable connector to the board.
5.
Remove the switch cover plate from the cabinet. Four #1 Phillips screws
(with washers) secure the cover plate to the blower exhaust shield. The
screw heads are visible on the blower exhaust shield as shown in
6.
Use a 7-mm wrench to remove the 4 nuts that hold the switch board to the
blower exhaust shield.
7.
Remove the switch board.
Figure 60. Clock Switch Board
Switch Connector
Switch Nuts
Cover Plate
Screws
Exhaust Shield