AC Repair and Adjustment Procedures
FRP 32: Voltage Selector Switch (SW1) Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
165
b. Pull the cover straight up, then remove it from the cabinet. Be careful
not to damage the inlet air thermistors or the EMI gasket on the bottom
of the cover.
5.
Carefully record the positions of the wires that connect to the switch.
Double-check the list for accuracy.
6.
Use a large Phillips or flatblade screwdriver to remove the wires. (It may
be helpful to loosen the switch [refer to
] before you remove all of
the wires.)
7.
Use a #2 Phillips screwdriver to remove the screws that secure the switch
to the bottom of the power box.
8.
Remove the switch.
9.
If necessary, remove the jumpers from the back of the old switch and
install them in the same positions on the replacement switch.
Figure 74. Voltage Selector Switch Location
Cabinet Front
(power supply insertion side)
Cabinet Rear
(module insertion side)
Voltage
Selector
Switch