AC Repair and Adjustment Procedures
FRP 13: Boundary Scan Cable/Wire Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
97
6.
From the wiremat side, gently pull the connector block up toward the
other rail connectors.
7.
Ensure the proper orientation of the connector, then position the
connector in the connector slot, and insert the hex screws (and brass
spacer if applicable). Tighten the screws to 15 in-oz.
8.
Install the connector spring and center it in relation to the connector
block.
9.
Push the connector toward the spring to ensure that the connector moves
laterally, then springs back into position.
10. Insert the foam plug in each connector slot.
11. If applicable, connect the boundary scan wire(s) in the wiremat.
12. Use tie wraps to secure the clock wire in the wiremat.
13. If applicable, close the air seals on the cable ducts where wires pass
between cabinets.
14. Replace and cam the modules that you removed. Refer to
FRP 5
.
15. Reinstall any panels that you removed earlier.
16. Return the system to operation, ensure proper function, and close the
cabinet doors.