AC Repair and Adjustment Procedures
FRP 12: Clock Wire Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
85
9.
Push the connector toward the spring to ensure that the connector moves
laterally, then springs back into position.
10. Insert the foam plug in each connector slot.
11. Use tie wraps to secure the clock wire in the wiremat.
12. If applicable, close the air seals on the cable ducts where wires pass
between cabinets.
13. Replace and cam the modules that you removed. Refer to
FRP 5
.
14. Reinstall any panels that you removed earlier.
15. Return the system to operation, ensure proper function, and close the
cabinet doors.