FRP 31: Power Supply Circuit Breaker (CB2 through CB7) Replacement
AC Repair and Adjustment
Procedures
160
Cray Research/Silicon Graphics Proprietary
HMM-168-A
FRP 31: Power Supply Circuit Breaker (CB2 through CB7)
Replacement
Part Number
•
57176100 (circuit breaker, 20A 480V)
Tools Required
•
#1 Phillips screwdriver
•
#2 Phillips screwdriver
•
Small flatblade screwdriver
Circuit Breaker Removal
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet. Place a lockout device over the cabinet’s plug and lock/tag it.
You may also open, lock, and tag the customer’s wall breaker(s).
3.
Remove the air filter. Refer to
FRP 37
for removal instructions.
WARNING
Ensure that the electrical plug for the
equipment that you service is
unplugged, locked, and tagged. Failure
to do so could result in severe shock
and burns.