OMMANDS
In the count up/down format, one input takes each pulse as a positive step command, and
another takes each pulse as a negative step command, as shown below.
The drive can be set to increment position on the rising or falling edge of the signal.
Stepping resolution can be programmed for electronic gearing.
Q
UADRATURE
F
ORMAT
C
OMMANDS
In quadrature format, A/B quadrature commands from a master encoder (via two inputs)
provide velocity and direction commands, as shown below.
The ratio can be programmed for electronic gearing.
Up Input
Velocity
Command
Down Input
B Input
Velocity
Command
A Input