Accelnet Plus Micro Modules User Guide
16-01687 Rev 03
Copley Controls
Page 48 of 139
H
IGH
S
PEED
I
NPUT
:
IN7
A
NALOG
I
NPUT
:
AIN1
As a reference input it takes Position/Velocity/Torque commands from a controller.
If not used as a command input, it can be used as general-purpose analog input.
D
IGITAL
O
UTPUTS
:
O
UT
1~O
UT
6
Digital outputs [OUT1~3] are HCT CMOS inverters. They operate from +5V and can source/sink 4 mAdc.
[OUT4~6] are LVC CMOS inverters. They operate from 3.3V and can source/sink 24 mA.
The output functions shown below are programmable to turn the output ON (HI) or OFF (LO) when active.
OUTPUT FUNCTIONS
•
Fault
• rake
• Custom event
• P M Sync
• Custom Trajectory status
•
Custom position-triggered
output
• Program control
SPECIFICATIONS
Input
Data Notes
Input
Voltages
HI
V
T
≥ 1.3 2.0 dc
LO
V
T
-
≤
0.55~1.3 Vdc
Hys
V
H
=
0.40~0.79 Vdc
Max +6 Vdc
Min
0 Vdc
Pull-up
R1
10 kΩ
Low Pass
Filter
R2
1 kΩ
C1
100 pF
RC
0.1 µs *
CONNECTIONS
Signal J2 Pins
IN7
11
100p
7 CT2G1
5V
5V
1
10k
IN7
SGND
2 AEV, APV
SPECIFICATIONS
Spec
Data Notes
Input Voltage
Vref
±10 Vdc
Input Resistance
Rin
5.09 k
Ω
CONNECTIONS
AIN1
Signal
J2 Pins
Ref(+) REFIN(+)
2
Ref(-) REFIN(-)
1
CONNECTIONS
Outputs Signal
J2
Pins
OUT1
DOUT1
13
OUT2
DOUT2
12
OUT3
DOUT3
15
OUT4
DOUT4
14
OUT5
DOUT5
17
OUT6
DOUT6
16
J2 Sgnd Pins (APV)
3,4,18,31,32,33,34,42,49,50,59,60 (19~24)
•
Digital, non-isolated
•
Programmable functions
•
MISO Input when SLI port is in use
5 Vdc
O U T 1 3
7 CT2G1
3.3 Vdc
O U T 6
2 mA
SG N D
7 VC3G1
mA
SGN D
2 AEV, APV
2 AEV, APV
* RC time constant applies
when input is driven by an
active High/Low device.