Accelnet Plus Micro Modules User Guide
16-01687 Rev 03
Copley Controls
Page 47 of 139
H
IGH
S
PEED
I
NPUTS
:
IN1,
IN2,
IN3,
IN4,
IN5,
1N6
The six digital inputs to the AEV are programmable to a selection of functions.
All have 100 ns C filters when driven by active sources (CMOS, TT , etc) and all have 10 kΩ pull
-up resistors to +5 Vdc.
In addition to the selection of functions, the active level for each input is individually programmable.
Input level
functions
have programmable HI or LO to activate the function.
Input transition
functions are programmable to activate on LO -> HI, or HI -> LO transitions.
INPUT LEVEL FUNCTIONS
• Drive Enable, Enable with Clear aults,
Enable with Reset
• P M Sync
• Positive imit Switch
• Negative imit Switch
• ome Switch
• Encoder ault
• Motor Temperature Sensor Input
•
Motion Abort
• igh
-Resolution Analog Divide
INPUT TRANSITION FUNCTIONS
• Clear aults and Event atch
• Drive eset
• P M Sync Input
• Trajectory Update
• Count Input Edges, Save to egister
• igh
-Speed Position Capture *
• Simulated Absolute Encoder ur
st
• Abort Move if N Counts rom
Destination in Register
SPECIFICATIONS
Input
Data Notes
Input
Voltages
HI
V
T
≥ 1. 2 2.3 Vdc
LO
V
T
-
≤ 0.6 1.6 Vdc
Hys
V
H
= 0.44~1.26
Max
+6 Vdc
Min
0 Vdc
Pull-up
R1
10 kΩ
Low Pass
Filter
R2
1 kΩ
C1
100 pF
RC
1
0.1 µs
CONNECTIONS
Signal
J2 Pins
IN1
5
IN2
6
IN3
7
IN4
8
IN5
9
IN6
10
* Encoder index pulse capture
2.5 us minimum pulse width,
0.1 us between active edge of input and
capture of position,
5 us minimum pulse
100p
7 VC3G1
5V
5V
1
10k
IN1 6
SGND
2 AEV, APV
J2 Sgnd Pins (APV)
3,4,18,31,32,33,34,42,49,50,59,60