Accelnet Plus Micro Modules User Guide
16-01687 Rev 03
Copley Controls
Page 32 of 139
AEV
PC
B
OARD
C
ONNECTORS AND
P
INOUT
Signal
P3
Pin
Signal
Reserved 6
3
6
4
Reserved
Reserved 6
1
6
2
Reserved
SGND
5
9
6
0
SGND
+5VENC
5
7
5
8
+5VENC
ENCX2
5
5
5
6
/ENCX2
ENCB2
5
3
5
4
/ENCB2
ENCA2
5
1
5
2
/ENCA2
SGND
4
9
5
0
SGND
ENCX1
4
7
4
8
/ENCX1
ENCB1
4
5
4
6
/ENCB1
ENCA1
4
3
4
4
/ENCA1
HALLW
4
1
4
2
SGND
HALLU
3
9
4
0
HALLV
COS1-
3
7
3
8
COS1+
SIN1-
3
5
3
6
SIN1+
SGND
3
3
3
4
SGND
SGND
3
1
3
2
SGND
ECATTX1-
2
9
3
0
ASYNC_TxD
2
7
2
8
ASYNC_RxD
ECATTX2-
2
5
2
6
ECATRX1-
2
3
2
4
+3.3V_TXRX2
2
1
2
2
ECATRX2-
+3.3V_TXRX1
1
9
2
0
(SLI-CLK)
DOUT5
1
7
1
8
SGND
(BRAKE) DOUT3
1
5
1
6
DOUT6 (SLI-
EN1)
DOUT1
1
3
1
4
DOUT4 (SLI-
MOSI)
(SLI-MISO) IN7
1
1
1
2
DOUT2
IN5
9
1
0
IN6
IN3
7
8
IN4
(Enable) IN1
5
6
IN2
SGND
3
4
SGND
REFIN(-)
1
2
REFIN(+)
J2 SIGNAL
Signal
J3 Pin
Signal
STO_1
1
3
STO_2
STO1_RTN
2
4
STO2_RTN
J3 SAFETY
TOP VIEW
Viewed from above looking down
on the connectors or PC board
footprint to which the module is
mounted
Signal P3 Pin Signal
MOTU
37 38
MOTU
35 36
33 34
31 32
MOTV
29 30
MOTV
29 28
25 26
23 24
MOTW
21 22
MOTW
19 20
17 18
15 16
HVCOM
13 14
HVCOM
11 12
9 10
7
8 VLOGIC
+HV
5
6
+HV
3
4
1
2
J1 POWER & MOTOR
J3: Safety
Dual row, 2 mm centers
4 position female header
SAMTEC TLE-102-01-G-DV-TR
J2: Signal
Dual row, 0.050 inch centers
64 position female header
SAMTEC: FLE-132-01-G-DV-K-TR
J1: HV & Motor
Dual row, 2 mm centers
38 position female header
SAMTEC: SQT-119-01-G-D