Accelnet Plus Micro Modules User Guide
16-01687 Rev 03
Copley Controls
Page 26 of 139
T
HERMALS
O
UTPUT
P
OWER
D
ISSIPATION VS
.
O
UTPUT
C
URRENT AND
+HV
AEV,
APV,
AEZ,
APZ
Draw a vertical line using the effective output current during a typical motion cycle. Find
the intersection with a curve closest to the +HV from the power supply. Draw a horizontal
line from there to the left which will show the losses in Watts. On the following page find
the VLOGIC power dissipation. Add these together to produce the total Watts of losses.
AEV-090-14
AEV-090-30
APV-090-14
APV-090-30
AEV-090-50,
AEZ-090-50
AEV-090-50-C,
AEZ-090-50-C
APV-090-50,
APZ-090-50
APV-090-50-C,
APZ-090-50-C
In this example, the application output
current is 22 Adc. At +HV = 85 Vdc the PWM loss