Accelnet Plus Micro Modules User Guide
16-01687 Rev 03
Copley Controls
Page 46 of 139
CME
D
EFAULTS
These tables show the CME default settings. They are user-programmable and
the settings can be saved to non-volatile flash memory as CCX or CCD files.
Input / Output > Digital Inputs
Name
Configuration
IN1
Amp Enable-LO Enables with Clear Faults
IN2
Not Configured
IN3
Not Configured
IN4
Not Configured
IN5
Motor Temp-Hi Disables
IN6
Encoder Fault-Active HI
IN7*
SLI MISO (Master Input Slave Output)
Configure Filters > Filter Settings
Name
Notes
Analog
Reference
Disabled
V Loop Input
Disabled
V Loop Output 1
Low Pass, Butterworth,
2 poles, 200 Hz
V Loop Output 2 Disabled
V Loop Output 3 Disabled
I Loop Input 1
Disabled
I Loop Input 2
Disabled
Input Shaping
Disabled, 0.1 Poles
Home
Software Limits
Positive, Negative, Deceleration
Method
Set Current Position as Home
Fast Velocity
RPM
Slow Velocity
RPM
Accel / Decel
RPS
Offset
Counts
Homing Adjustment Counts
Input / Output > Digital Outputs
Name
Notes
OUT1
Fault-Active LO
OUT2
Not Configured
OUT3
Brake-Active Low
OUT4*
SLI MOSI (Master Output Slave Input)
OUT5*
SLI CLK (Clock)
OUT6*
SLI SS (Slave Select)
* If not used for an SLI port, these outputs
can be programmed for other functions
Configure Faults > Latched Faults
Active
Notes
√
Short Circuit
√
Amp Over Temperature
√
Motor Over Temp
Over Voltage
Under Voltage
√
Feedback Error
Motor Phasing Error
√
Following Error
Command Input Lost
Motor Wiring Disconnected
STO Active
Configure Faults > Optional Faults
Active
Notes
Over Current (Latched)
√
These are the default settings for Latched Faults. Using
CME, these can be checked or unchecked.