Accelnet Plus Micro Modules User Guide
16-01687 Rev 03
Copley Controls
Page 79 of 139
EZ
B
OARD
I
NDICATORS
D
RIVE
S
TATUS
I
NDICATOR
AEZ EtherCAT
APZ CANopen
STATUS
LED
The bi-color AMP LED gives the state of the drive.
Colors do not alternate, and can be solid ON or blinking.
When multiple conditions occur, only the top-most condition will be displayed.
When that condition has been cleared the next one below will be shown.
Red/Blinking
= Latching fault. Operation will not resume until drive is Reset.
Red/Solid
= Transient fault condition. Drive will resume operation when
the condition causing the fault is removed.
Green/Double-Blinking = STO circuit active, drive outputs are Safe-Torque-Off
Green/Slow-Blinking
= Drive OK but NOT-enabled. Will run when enabled.
Green/Fast-Blinking
= Positive or Negative limit switch active.
Drive will only move in direction not inhibited by limit switch.
Green/Solid
= Drive OK and enabled.
Will run in response to reference inputs or commands from
CAN or EtherCAT master
Off
= No HV or VLOGIC power to drive
L
ATCHING
F
AULTS
(*
D
EFAULT
)
O
PTIONAL
F
AULTS
Short circuit (Internal or external)
Over-current (Latched, I
2
T)
Drive over-temperature
Over-voltage
Motor over-temperature
Under-voltage
Feedback Error
Motor Phasing Error
Following Error
Command Input Lost
Motor Wiring Disconnected
STO Active