Accelnet Plus Micro Modules User Guide
16-01687 Rev 03
Copley Controls
Page 28 of 139
M
AXIMUM
O
PERATING
T
EMPERATURE VS
.
O
UTPUT
C
URRENT
This chart shows the maximum operating temperature for the drive based on the mounting
and cooling options. Fan cooling applies when the it is mounted so that the airflow is
directed on to the drive to produce the CFM (Cubic Feet per Minute) values shown below.
45 °C is the maximum environmental temperature in which to operate the drive.
•
NHSNF
= No Heatsink, No Fan
•
NHSF100 = No Heatsink, Fan at 100 CFM
•
NHSF300 = No Heatsink, Fan at 300 CFM
•
HSNF
= With heatsink, No Fan
•
HSF100 = With heatsink, Fan at 100 CFM
•
HSF300 = With heatsink, Fan at 300 CFM
AEV-090-50,
APV-090-50
AEV-180-10,
APV-180-10
Example
The dashed lines above show that at an output current of 20 Adc, the maximum
operating temperature with a heatsink and fan at 100 CFM would be 32 °C (89 °F)
0
10
20
30
40
50
60
70
0
.0
2
.5
5
.0
7
.5
1
0
.0
1
2
.5
1
5
.0
2
0
.0
2
5
.0
Te
m
p
era
tu
re
°
C
Amps DC
NHSNF
NHSF100
NHSF300
HSNF
HSF100
0
10
20
30
40
50
60
70
0.0 2.5 5.0 7.5 10.0 12.5 15.0
D
ecre
es
°C
Amps DC
NHSNF
NHSF100
NHSF300
HSNF
HSF100