ELECTRICAL COMPONENTS
Ground Straps
Page 12-36 2001 Pioneer 1200 Gasoline Vehicle Maintenance and Service Manual
12
∆ WARNING
• If the battery is frozen or the container is bulged, discard battery. A frozen battery can
explode.
6. The frequency of recharging required depends on the temperature of the storage area, but it is recom-
mended that the battery be monitored for state of charge every month. Also, if the storage area is
unheated in a cold climate and recharging is required, it is recommended that the area be heated to at
least 60 °F (16 °C) prior to charging. The battery will not charge effectively in cold temperatures for the
same reasons that it does not discharge as rapidly in cold temperatures.
Charging a Dead Battery
Read DANGER and WARNING on page 12-1 and DANGER on page 12-31.
The vehicle is equipped with a starter/generator. The generator is not designed to charge a dead battery. If
the vehicle battery has become discharged, it must be charged using a properly rated automotive type
charger.
∆ WARNING
• Do not jump-start a dead battery using another battery and jumper cables.
GROUND STRAPS
Testing the Ground Straps