1-50
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
78-17235-01
Chapter 1 General Troubleshooting
1.9 CTC Operation Troubleshooting
For example:
ping 192.1.0.2
Step 3
If the workstation has connectivity to the node, the ping is successful and displays a reply from the IP
address. If the workstation does not have connectivity, a “Request timed out” message appears.
Step 4
If the ping is successful, an active TCP/IP connection exists. Restart CTC.
Step 5
If the ping is not successful and the workstation connects to the node through a LAN, check that the
workstation’s IP address is on the same subnet as the ONS 15310-CL or ONS 15310-MA.
Step 6
If the ping is not successful and the workstation connects directly to the node, check that the link light
on the workstation’s NIC is illuminated.
1.9 CTC Operation Troubleshooting
This section contains troubleshooting procedures for CTC login or operation problems.
1.9.1 Unable to Launch CTC Help After Removing Netscape
Symptom
After removing Netscape and running CTC using Internet Explorer, the user is unable to launch
the CTC Help and receives an “MSIE is not the default browser” error message.
Table 1-6
describes the potential cause of the symptom and the solution.
Set Internet Explorer as the Default Browser for CTC
Step 1
Open the Internet Explorer browser.
Step 2
From the menu bar, click
Tools > Internet Options
. The Internet Options window appears.
Step 3
In the Internet Options window, click the
Programs
tab.
Step 4
Click the
Internet Explorer should check to see whether it is the default browser
check box.
Step 5
Click
OK
.
Step 6
Exit any and all open and running CTC and Internet Explorer applications.
Table 1-6
Unable to Launch CTC Help After Removing Netscape
Possible Problem
Solution
Loss of association
between browser and
Help files.
When the CTC software and Netscape are installed, the Help files are
associated with Netscape by default. When you remove Netscape, the Help
files are not automatically associated with Internet Explorer as the default
browser.
Set Internet Explorer as the default browser so that CTC will associate the
Help files to the correct browser.
See the
“Set Internet Explorer as the Default Browser for CTC” procedure
on page 1-50
to associate the CTC Help files to the correct browser.