1-16
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
78-17235-01
Chapter 1 Alarm Troubleshooting
1.5.4 Alarm Hierarchy
Facility (port) alarms also follow a hierarchy; lower-ranking alarms are closed by higher-ranking alarms.
The facility alarm hierarchy used in the systems is shown in
Table 1-10
.
Near-end failures and far-end failures follow different hierarchies. Near-end failures stand according to
whether they are for the entire signal (LOS, loss of frame alignment [LOF]), facility (AIS-L), path
(AIS-P, etc.) or VT (AIS-V, etc.). The full hierarchy for near-end failures is shown in
Table 1-11
. This
table is taken from Telcordia GR-253-CORE.
—
UNEQ-P
Lowest
TIM-P
Table 1-9
Path Alarm Hierarchy
Priority
Condition Type
Table 1-10
Facility Alarm Hierarchy
Priority
Condition Type
Highest
LOS
—
LOF
—
AIS-L
—
SF-L
—
SD-L
—
RFI-L
—
TIM-S
—
AIS-P
—
LOP-P
—
SF-P
—
SD-P
—
UNEQ-P
—
TIM-P
Lowest
PLM-P
Table 1-11
Near-End Alarm Hierarchy
Priority
Condition Type
Highest
LOS
—
LOF
—
AIS-L
—
AIS-P
1
—
LOP-P
2
—
UNEQ-P
—
TIM-P
—
PLM-P