1-19
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
78-17235-01
Chapter 1 Error Messages
EID-3097
The ring termination is in use.
The ring termination you are trying to
access is in use. Try after sometime.
EID-3098
No ring terminations selected.
Select one of the ring terminations.
EID-3099
Sorry, entered key does not match existing authentication key.
Check the authentication key and reenter.
EID-3100
Error encountered during authentication.
There was an error in authentication. Verify
that the key does not exceed the character
limit .
EID-3101
DCC Metric is not in the range 1 - 65535.
The DCC metric should be in the range of 1
to 65535.
EID-3102
Invalid DCC Metric
There was an invalid DCC metric.
EID-3103
Invalid IP Address: {0}
The IP address is invalid.
EID-3104
Router priority is not in the range of 0 - 255
The router priority should be in the range of
0 to 255.
EID-3105
Invalid Router Priority
The router priority is invalid.
EID-3106
Hello Interval is not in the range of 1 - 65535
The hello interval should be in the range of
1 to 65535.
EID-3107
Invalid Hello Interval
The hello interval is invalid.
EID-3109
Invalid Dead Interval value. Valid range is 1 - 2147483647
The dead interval value must be between 1
and 2147483647.
EID-3110
Dead Interval must be larger than Hello Interval
Refer to the error message text.
EID-3111
LAN transit delay is not in the range of 1 - 3600 seconds
The LAN transit delay should be in the
range of 1 to 3600 seconds.
EID-3112
Invalid Transmit Delay
The transmit delay is invalid.
EID-3113
Retransmit Interval is not in the range 1 - 3600 seconds
The retransmit interval should be in the
range of 1 to 3600 seconds.
EID-3114
Invalid Retransit Interval
The retransmit interval is invalid.
EID-3115
LAN Metric is not in the range 1 - 65535.
The LAN metric should be in the range of 1
to 65535.
EID-3116
Invalid LAN Metric
The LAN metric is invalid.
EID-3117
If OSPF is active on LAN, no DCC Area Ids may be 0.0.0.0.
Please change all DCC Area Ids to non-0.0.0.0 values before
enabling OSPF on the LAN.
Refer to the error message text.
EID-3118
If OSPF is active on LAN, LAN Area ID may not be the same
as DCC Area Id.
LAN must be part of a different OSPF area
other than the DCC network.
EID-3119
Validation Error
CTC was unable to validate the values
entered by the user. This error message is
common to several different provisioning
tabs within CTC (examples include the
SNMP provisioning tab, the General>
Network provisioning tab, the Security >
Configuration provisioning tab, etc.).
Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
Description
Содержание ONS 15310-CL
Страница 22: ...Figures xxii Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 ...
Страница 32: ...xxxii Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 About this Guide ...
Страница 332: ...Index IN 14 Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 ...