1-79
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
78-17235-01
Chapter 1 Alarm Troubleshooting
1.7.116 INHSWPR
1.7.116 INHSWPR
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA) for ONS 15310-MA
SONET Logical Object: EQPT
The Inhibit Switch To Protect Request on Equipment condition occurs on traffic cards when the ability
to switch to protect has been disabled. If the port is part of a 1+1 protection scheme, traffic remains
locked onto the working system.
Clear the INHSWPR Condition
Step 1
If the condition is raised against a 1+1 port, complete the
“Initiate a 1+1 Manual Switch Command”
procedure on page 1-149
.
Step 2
If the condition does not clear, log into the Cisco Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
1.7.117 INHSWWKG
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA) for ONS 15310-MA
SONET Logical Object: EQPT
The Inhibit Switch To Working Request on Equipment condition occurs on ONS 15310-MA traffic cards
when the ability to switch to working has been disabled. If the card is part of a 1+1 protection scheme,
traffic remains locked onto the protect system.
Step 1
If the condition is raised against a 1+1 port, complete the
“Initiate a 1+1 Manual Switch Command”
procedure on page 1-149
.
Step 2
If the condition does not clear, log into the Cisco Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
1.7.118 INTRUSION-PSWD
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: NE
The Security Intrusion Incorrect Password condition occurs after a Superuser attempts a settable number
of unsuccessful logins, a login with an expired password, or an invalid password. The alarmed user is
locked out of the system, and INTRUSION-PSWD condition is raised. This condition is only shown in
Superuser login sessions, not in login sessions for lower-level users. The INTRUSION-PSWD condition
is automatically cleared when a settable lockout timeout expires, or it can be manually cleared in CTC