Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
78-17235-01
Chapter 1 Alarm Troubleshooting
1.7.17 APS-PRIM-SEC-MISM
1.7.17 APS-PRIM-SEC-MISM
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: OCN
The Optimized 1+1 APS Primary Section Mismatch condition occurs on OC-N ports in an optimized
1+1 protection system if there is a mismatch between the primary section of the local node facility and
the primary section of the remote-node facility.
Clear the APS-PRIM-SEC-MISM Alarm
Step 1
Ensure that the local node and remote-node ports are correctly provisioned the same way. For more
information about optimized 1+1 configurations, refer to the “Turn Up Node” chapter in the
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide
.
Step 2
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1 800 553-2447).
1.7.18 AS-CMD
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: BPLANE, CE100T, DS1, DS3, EC1, EQPT, NE, OCN, PWR
DWDM Logical Objects: PPM, SHELF
The Alarms Suppressed by User Command condition applies to the network element (NE object), a
single card, or a port on a card. It occurs when alarms are suppressed for that object and its subordinate
objects. For example, suppressing alarms on a card also suppresses alarms on its ports.
Note
For more information about suppressing alarms, refer to the “Manage Alarms” chapter in the
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide
.
Clear the AS-CMD Condition
Step 1
For all nodes, in node view, click the
Conditions
tab.
Step 2
Click
Retrieve
. If you have already retrieved conditions, look under the Object column and Eqpt
Type
column and note what entity the condition is reported against—such as a port, slot, or shelf.
•
If the condition is reported against a slot and card, alarms were either suppressed for the entire card
or for one of the ports. Note the slot number and continue with
Step 3
.
•
If the condition is reported against the NE object, go to
Step 7
.
Step 3
Determine whether alarms are suppressed for a port and if so, raise the suppressed alarms by completing
the following steps:
a.
Double-click the card to display the card view.
b.
Click the
Provisioning > Alarm Profiles > Alarm Behavior
tabs and complete one of the following
substeps: