Chapter 1 Alarm Troubleshooting
1.7.19 AS-MT
•
If the Suppress Alarms column check box is checked for a port row, deselect it and click
Apply
.
•
If the Suppress Alarms column check box is not checked for a port row, click
View > Go to Previous View
.
Step 4
If the AS-CMD condition is reported for a card and not an individual port, in node view click the
Provisioning > Alarm Profiles > Alarm Behavior
tabs.
Step 5
Locate the row number for the reported card slot.
Step 6
Click the
Suppress Alarms
column check box to deselect the option for the card row.
Step 7
If the condition is reported for the shelf, cards and other equipment are affected. To clear the alarm,
complete the following steps:
a.
In node view, click the
Provisioning > Alarm Profiles > Alarm Behavior
tabs if you have not
already done so.
b.
Click the
Suppress Alarms
check box located at the bottom of the window to deselect the option.
c.
Click
Apply
.
Step 8
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).
1.7.19 AS-MT
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: CE100T, DS1, DS3, EC1, EQPT, OCN
DWDM Logical Objects: PPM, SHELF
The Alarms Suppressed for Maintenance Command condition applies to OC-3, OC-12, and electrical
ports and occurs when a port is placed in the Out-of-Service and Management, Maintenance
(OOS-MA,MT) service state for loopback testing operations.
Clear the AS-MT Condition
Step 1
Complete the
“Clear an OC-N Port Facility or Terminal Loopback Circuit” procedure on page 1-157
.
Step 2
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).
1.7.20 AS-MT-OOG
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: STSTRM, VT-TERM
The Alarms Suppressed on an Out-Of-Group VCAT Member alarm is raised on an STS or VT member
of a virtual concatenated (VCAT) group whenever the member is in the IDLE (AS-MT-OOG)
administrative state. This alarm can be raised when a member is initially added to a group. In IDLE
(AS-MT-OOG) state, all other alarms for the STS or VT are suppressed.