1-35
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
78-17235-01
Chapter 1 Error Messages
WID-5051
Unable to transition port state indirectly because the port
aggregates OCH CC circuits: if the port state should be
changed, edit it directly via port provisioning
Refer to the warning message text.
EID-5052
The operation is not valid for the connection type
You may have selected the incorrect switch.
EID-5053
The operation cannot be performed because the connection is
under test access
Refer to the error message text.
EID-5054
TL1 Tunnel Open Failed: {0}
Refer to the error message text.
EID-5055
Some patchcords were not deleted. Patchcords cannot be
deleted if they are incomplete or support any circuits, or if the
nodes supporting them are not connected.
Refer to the error message text.
EID-5056
This PPC cannot be deleted because one or more circuits are
provisioned over it.
Remove the circuits provisioned over the
provisionable patchcord before trying to
delete it.
EID-5057
Adding last node not completed yet.
Please wait before trying to add new node.
Refer to the error message text.
EID-5058
OCHNC Upgrade is applicable only to bidirectional circuits.
Refer to the error message text.
EID-5059 OCHNC
upgrade
failed.
One or more communication failures occurred during the
operation.
CTC encountered a complete failure while
upgrading optical channel network
connection.
EID-5060
OCHNC upgrade partially failed.
One or more communication failures occurred during the
operation.
Create the OCH CC manually.
CTC encountered a partial failure while
upgrading an optical channel network
connection.
EID-5061
Overhead circuit source and destination must reside on the
same shelf.
Refer to the error message text.
EID-6000
Platform does not support power monitoring thresholds
Refer to the error message text.
EID-6001
One of the XC cards has failures or is missing.
Check whether all the cross-connect cards
are installed and working.
EID-6002
One of the XC cards is locked.
Unlock the cross-connect card.
EID-6003
Unable to create OSC termination.
Ring ID already assigned.
Enter a new ID for the ring.
EID-6004
Unable to perform a system reset while a BLSR ring is
provisioned on the node.
Remove the BLSR from the node and
continue with the reset procedure.
EID-6005
Could not assign timing references:
- Only two DS1 or BITS interfaces can be specified.
- DS1 interfaces cannot be retimed and used as a reference
- BITS-2 is not supported on this platform.
Refer to the error message text.
Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
Description
Содержание ONS 15310-CL
Страница 22: ...Figures xxii Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 ...
Страница 32: ...xxxii Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 About this Guide ...
Страница 332: ...Index IN 14 Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 ...