1-14
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
78-17235-01
Chapter 1 Error Messages
EID-2218
Bandwidth must be between {0} and {1} percent.
The bandwidth must be within the specified
parameters.
EID-2219
Protection operation failed, XC loopback is applied on
cross-connection.
As the protection operation failed, a
cross-connect (XC) loopback will be
applied on cross-connection.
EID-2220
The tunnel status is PARTIAL. CTC will not be able to change
it. Please try again later
Refer to the error message text.
EID-2221
Cannot find a valid route for the unprotected to {0} upgrade
request.
Refer to the error message text.
EID-2222
One or more of the following nodes are currently part of a
4-fiber {0}. Only a single 4-fiber {0} is supported per node.
{1}
The nodes, specified by {1}, are already
part of a 4-fiber BLSR/MS-SPRing type
(specified by {0}).
EID-2223
Only one circuit can be upgraded at a time.
Refer to the error message text.
EID-2224
This link may not be included as it terminates on the source.
Refer to the error message text.
EID-2225
No valid signal while trying to complete the roll. (0)
Roll can be completed only when a valid
signal is detected. If not, the roll completion
may result in an error.
EID-2226
Circuit roll failure.
{0}
Refer to the error message text.
EID-2320
This VCAT circuit does not support deletion of its member
circuits.
You can not delete a circuit that is a member
of VCAT circuit.
EID-2321
Error deleting member circuits.
{0}
Refer to the error message text.
WID-2322
Not all cross-connects from selected circuits could be merged
into the current circuit. They may appear as partial circuits.
Refer to the warning message text.
EID-2323
Circuit roll failure.
Bridge and roll is not supported on a monitor circuit.
A monitor circuit does not support Bridge
and Roll.
EID-2324
Circuit upgrade error.
{0}
Refer to the error message text.
EID-2325
You have failed {0} times to unlock this session. CTC will exit
after you click OK or close this dialog box.
The maximum amount of attempts to
unlock this session has been reached.
WID-2326
Currently, CTC does not support bridge and roll on circuits that
are entirely created by TL1. To continue with bridge and roll in
CTC, selected circuits must be upgraded.
OK to upgrade selected circuits and continue bridge and roll
operation?
Refer to the warning message text.
WID-2327
Currently, CTC does not support bridge and roll on circuits that
are partially created by TL1. To continue with bridge and roll
in CTC, selected circuits must be upgraded.
OK to upgrade selected circuits and continue bridge and roll
operation?
Refer to the warning message text.
Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
Description
Содержание ONS 15310-CL
Страница 22: ...Figures xxii Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 ...
Страница 32: ...xxxii Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 About this Guide ...
Страница 332: ...Index IN 14 Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 ...