1-109
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
78-17235-01
Chapter 1 Alarm Troubleshooting
1.7.169 MANSWTOTHIRD
The Manual Switch To Second Reference condition occurs when the NE timing source is manually
switched to a second timing source.
Note
MANSWTOSEC is an informational condition and does not require troubleshooting.
1.7.169 MANSWTOTHIRD
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: EXT-SREF, NE-SREF
The Manual Switch To Third Reference condition occurs when the NE timing source is manually
switched to a third timing source.
Note
MANSWTOTHIRD is an informational condition and does not require troubleshooting.
1.7.170 MANUAL-REQ-SPAN
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: OCN
The Manual Switch Request on span condition occurs when a user initiates a Manual Span command to
move traffic from a working span to a protect span. This condition appears on the network view Alarms,
Conditions, and History tabs. The port where the MANUAL SPAN command was applied is marked with
an “M” on the network view detailed circuit map.
Clear the MANUAL-REQ-SPAN Condition
Step 1
Complete the
“Clear an External Switching Command on a Path Protection Span” procedure on
page 1-153
.
Step 2
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).
1.7.171 MATECLK
Default Severity: Minor (MN) for ONS 15310-MA
SONET Logical Object: EQPT
The Mate Clock alarm occurs when the active CTX2500 cannot detect the clock from the standby
CTX2500.