1-10
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
78-17235-01
Chapter 1 Alarm Troubleshooting
1.4 Alarm List by Logical Object Type
1.4 Alarm List by Logical Object Type
Table 1-8
lists all ONS 15310-CL and ONS 15310-MA Release 7.0 alarms and logical objects as they
are given in the system alarm profile. The list entries are organized by logical object name and then by
alarm or condition name. Where appropriate, the alarm entries also contain troubleshooting procedures.
Note
The list is given here exactly as it is shown in CTC, and in some cases does not follow alphabetical order.
STSMON
STS alarm detection at the monitor point (upstream from the cross-connect).
Note
The network element reports alarms or conditions on ingress ports of the
card. Alarms detected at the internal ports (TERM side) will be ingress
mapped to the MON side. The alarm profile entities of STSMON, if
available, should be changed to the same severity as the customized
severity for a specific STS alarm.
STSTRM
STS alarm detection at termination (downstream from the cross-connect).
Note
The network element reports alarms or conditions on ingress ports of the
card. Alarms detected at the internal ports (TERM side) will be ingress
mapped to the MON side. The alarm profile entities of STSTRM, if
available, should be changed to the same severity as the customized
severity for a specific STS alarm.
VCG
Virtual concatenation group.
VT-MON
VT1 alarm detection at the monitor point (upstream from the cross-connect).
Note
The network element reports alarms or conditions on ingress ports of the
card. Alarms detected at the internal ports (TERM side) will be ingress
mapped to the MON side. The alarm profile entities of VT-MON, if
available, should be changed to the same severity as the customized
severity for a specific VT alarm.
VT-TERM
VT1 alarm detection at termination (downstream from the cross-connect).
Note
The network element reports alarms or conditions on ingress ports of the
card. Alarms detected at the internal ports (TERM side) will be ingress
mapped to the MON side. The alarm profile entities of VT-TERM, if
available, should be changed to the same severity as the customized
severity for a specific VT alarm.
Table 1-7
Alarm Logical Object Type Definitions (continued)
Type
Definition
Table 1-8
ONS 15310-CL and ONS 15310-MA
Alarm List by Logical Object as Shown in Alarm Profile
BITS: AIS (NR)
EQPT: SFTWDOWN (MN)
OCN: SSM-STU (NA)
BITS: LOF (MN)
EQPT: SW-MISMATCH (NA)
OCN: STS-SQUELCH-L (NA)
BITS: LOS (MN)
EQPT: SWMTXMOD-PROT (CR)
OCN: SYNC-FREQ (NA)
BITS: SSM-DUS (NA)
EQPT: SWMTXMOD-WORK (CR)
OCN: TIM (CR)
BITS: SSM-FAIL (MN)
EQPT: WKSWPR (NA)
OCN: TIM-MON (MN)