Chapter 1 Error Messages
EID-3323
APC system is busy.
Automatic Power Control (APC) system is
busy.
EID-3324
No path to regulate.
There is no circuit path to regulate.
EID-3325
Requested action not allowed.
Generic DWDM provisioning failure
message.
EID-3326
Wrong input value.
The input value is incorrect.
EID-3327
Error in getting thresholds.
There was an error retrieving the thresholds.
This message is displayed only for the
OSCM/OSC-CSM line thresholds.
EID-3328
Error applying changes to row {0}.Value out of range.
There was an error applying the changes to
the specified row. The value is out of range.
EID-3330
Unable to switch to the byte because an overhead channel is
present on this byte of the port.
Refer to the error message text.
EID-3331
Error applying changes to row.
Refer to the error message text.
EID-3334
Cannot change timing parameters on protect port.
You cannot change timing parameters on
protect port.
EID-3335
The type of this port cannot be changed: SDH validation check
failed. Check if this port is part of a circuit, protection group,
SONET DCC, orderwire, or UNI-C interface.
Refer to the error message text.
EID-3336
Error on reading a control mode value.
The Control Mode must be retrieved.
EID-3337
Error on setting a set point gain value.
The Gain Set Point must be set.
EID-3338
Error on reading a set-point gain value.
The Gain Set Point must be retrieved.
EID-3339
Error on setting a tilt calibration value.
The tilt calibration must be set.
EID-3340
Error on setting expected wavelength.
The expected wavelength must be set.
EID-3341
Error on reading expected wavelength.
The expected wavelength must be retrieved.
EID-3342
Error on reading actual wavelength.
The actual wavelength must be retrieved.
EID-3343
Error on reading actual band.
The actual band must be retrieved.
EID-3344
Error on reading expected band.
The expected band must be retrieved.
EID-3345
Error on setting expected band.
The expected band must be set.
EID-3346
Error retrieving defaults from the node: {0}.
There was an error retrieving defaults from
the specified node.
EID-3347
Cannot load file {0}.
CTC cannot load the specified file.
EID-3348
Cannot load properties from the node.
Refer to the error message text.
EID-3349
Cannot save NE Update values to file.
Check your file system for space constraint
or any other problem.
EID-3350
Cannot load NE Update properties from the node:
Refer to the error message text.
EID-3351
File {0} does not exist.
The specified file does not exist.
EID-3352
Error on setting value at {0}.
There was an error while setting the value at
the specified location.
Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
Description
Содержание ONS 15310-CL
Страница 22: ...Figures xxii Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 ...
Страница 32: ...xxxii Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 About this Guide ...
Страница 332: ...Index IN 14 Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 ...