1-26
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
78-17235-01
Chapter 1 Error Messages
WID-3275
Make sure the Remote Interface ID and the Local Interface ID
on the two sides are matched. (Local Interface ID on this node
should equal Remote Interface ID on the neighbor node and
vice-versa.)
Refer to the warning message text.
WID-3276
Both {0} and {1} exist on the same selected port.
{2}
The specified port has both SDCC and
LDCC.
WID-3277
The description cannot contain more than {0} characters. Your
input will be truncated.
The input exceeds the character limit. The
value will be truncated to the maximum
chacter limit.
WID-3279
Card deleted, returning to shelf view.
CTC returns to node view.
WID-3280
ALS will not engage until both the protected trunk ports detect
LOS.
Refer to the warning message text.
WID-3282
Performing a software upgrade while TSC 5 is active could
result in a service disruption. It is recommended that you make
TSC 10 the active TSC by performing a soft reset of TSC 5. The
following 15600s are currently unsafe to upgrade...
Refer to the warning message text.
WID-3283
Before activating a new version, make sure you have a database
backup from the current version.
Refer to the warning message text.
WID-3284
Reverting to an older version.
CTC is being reverted to an older version of
application.
WID-3285
Applying FORCE or LOCKOUT operations may result in
traffic loss.
Refer to the warning message text.
WID-3286
The ring status is INCOMPLETE. CTC cannot determine if
there are existing protection operations or switches in other
parts of the ring. Applying a protection operation at this time
could cause a traffic outage. Please confirm that no other
protection operations or switches exist before continuing.
Refer to the warning message text.
WID-3287
There is a protection operation or protection switch present on
the ring. Applying this protection operation now will probably
cause a traffic outage.
Refer to the warning message text.
WID-3288
This ring status is INCOMPLETE. CTC will not be able to
apply this change to all of the nodes in the {0}.
Change the ring status to apply the change
to all nodes in the ring type.
EID-3290
Unable to delete specified provisionable patchcord(s).
Refer to the error message text.
EID-3291
Cannot change revertive behavior due to an active protection
switch.
Protection switch should not be active to
change the revertive behaviour.
EID-3292
Error resetting shelf.
CTC encountered an error while resetting
the node.
EID-3293
No such provisionable patchcord.
You are attempting to delete a provisionable
patchcord that does not exist. This happens
when multiple instances of CTC are
running and attempting to delete the same
provisionable patchcord concurrently.
Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
Description
Содержание ONS 15310-CL
Страница 22: ...Figures xxii Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 ...
Страница 32: ...xxxii Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 About this Guide ...
Страница 332: ...Index IN 14 Cisco ONS 15310 CL and Cisco ONS 15310 MA Troubleshooting Guide R7 0 78 17235 01 ...