D-4
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-07
Appendix D Chassis and Module LEDs
I/O Module LEDs
I/O Module LEDs
Table D-3
describes the I/O module LEDs.
Table D-3
I/O Module LEDs
LED
Status
Description
ID
Flashing blue
The operator has activated this LED to identify this module in the chassis.
Off
This module is not being identified.
Status
Green
All diagnostics pass. The module is operational (normal initialization
sequence).
Red
The module has detected a slot ID parity error and will not power on or boot up.
or
The module is not fully inserted, and it is not making a reliable connection with
the supervisor.
or
The module has failed diagnostic tests and has powered down.
Flashing red
The switch has just been powered on, and the module is resetting.
or
The module is resetting and both ejector levers are out.
or
The module has been inserted during the initialization process.
or
The module could not power up because of insufficient power.
or
An overtemperature condition has occurred. A major temperature threshold has
been exceeded during environmental monitoring.
Off
The module is not receiving power.
Link (for each port)
Green
The port is active (the link is connected and active).
Orange
The port is disabled by the operator or is not initializing.
Flashing orange
The port is faulty and disabled.
Off
The port is not active or the link is not connected.
Содержание Nexus 7004
Страница 12: ...Contents xii Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...
Страница 19: ... xix Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...
Страница 22: ... xxii Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...
Страница 24: ...xxiv Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 7 New and Changed Information ...