MR3P Series EXPAND SERIAL COMMAND FUNCTION SPECIFICATION
Software Engineer Division
8.9.3 CF_BLTINSP
COMMAND
COMMAND “CF_BLTINSP_%1”[CR]
%1
“ON”------ Select Built-in Speaker
“OFF”---- Cancel Boiling Speaker
Details
Set/Cancel Built-in Speaker. (Only valid when it is in the usual Power On
state.)
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10 Setting Series COMMAND
8.10.1 CF_BBACK COMMAND
COMMAND
“CF_BBACK_%1”[CR]
%1
“ON”------ Select Blue Back
“OFF”---- Cancel Blue Back
Details
Set/cancel Blue Back. (Only valid when it is in the usual Power On state.)
The value set is stored in EEPROM. When ALL OFF the projector, the
value will return to the original setting.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.2 CF_DISP COMMAND
COMMAND “CF_DISP_%1”[CR]
%1
“ON”------ Select Display
“OFF”----Cancel Display
Details
Set/Cancel Display. (Only valid when it is in the usual Power On state.)
The value set is stored in EEPROM. When ALL OFF the projector, the
value will return to the original setting.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.3 CF_LOGO COMMAND
COMMAND
“CF_
L
OGO_%1”[CR]
%1
“ON”------ Select Logo
“OFF”---- Cancel Logo
Details
Set/Cancel Logo. (Only valid when it is in the usual Power On state.)
The value set is stored in EEPROM. When ALL OFF the projector, the
value will return to the original setting.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
Page 32 / 53