MR3P Series EXPAND SERIAL COMMAND FUNCTION SPECIFICATION
Software Engineer Division
9.4.12 CR_PROGV COMMAND
COMMAND “CR_PROGV”[CR]
Details
Get Progressive setting status.
Acceptable
“000_%1”[CR]
%1
“L1”----- Progressive Mode L1 setting
“L2”----- Progressive Mode L2settiing
“OFF”--- Progressive cancellation
Response
Unacceptable “
?
”[CR]
9.4.13 CR_IMAGE COMMAND
COMMAND “CR_IMAGE”[CR]
Details
Get image setting status
Acceptable
“000_%1”[CR]
%1
“STAND”------ Standard
“REAL” ------
High contrast
“CINEMA”---- Cinema
“CUSTOM1”-- Custom
Response
Unacceptable
“Error Code”[CR] ---- Invalid
“
?
”[CR] -------------- When receives unclear Command
9.4.14 CR_IMGGMD COMMAND
COMMAND
“CR_IMGGMD”[CR]
Details
Get Standard/High Contrast/Cinema for image gamma setting.
Acceptable
“000_%1”[CR]
%1
“STD” ------ Standard
“REL” ------
High contrast
“CNM” ------ Cinema
Response
Unacceptable “
?
”[CR]
9.4.15 CR_APCTRL COMMAND
COMMAND “CR_APCTRL”[CR]
Details
Get digital keystone setting status.
Acceptable
“000_%1”[CR]
%1
“
L
1”---- Digital Keystone in operation with Level1
“
L
2”---- Digital Keystone in operation with Level2
“OFF”-- Digital Keystone is OFF
Response
Unacceptable “
?
”[CR]
Page 39 / 53